Atkore PG14

FOLD PAGE OUT! FPADS Construction: Double slit nylon (PA6) corrugated conduit. Colour: Black. Other colours available* Orange, White, Blue and Grey. Typical Applications: Retrofit and cable assemblies with pre terminated plugs. • Made from 2 interlocking slit corrugated conduits • Temperature range -40˚C to +120˚C • Cables can be inserted laterally • Provides abrasion resistance and routing of cables for static applications • Self extinguishing • Halogen, sulphur and phosphorus free • UV resistant • Other colours available* in 21mm and 28mm Grey, Blue, Orange and White FPPDS FPRDS FCL Nylon corrugated conduit clip with integral lid Nylon PA66 conduit clip with integral lid for increased security. Incorporates internal ribs to prevent corrugated conduit from pulling through, 20 kg with FPAS21. FCLAMP AB RINGS Non-metallic, heavy duty conduit clamp Nylon PA66, conduit fixing clamp for corrugated conduit. Suitable for use with with fine or coarse pitch conduits. Can be used with a range of accessories including cover plates and weld plates (available separately - see page 72). Abrasion Rings Provides additional mechanical protection from localised abrasion for corrugated conduits. Can be fixed anywhere along the conduit and internal ribs maintain desired location. Nylon PA66 construction and supplied as two half shells which interlock and secured using stainless steel self- tapping screws. FPADS part number reel length (m) outside dia (mm) inside dia (mm) min inside bend radius (mm) FPRDS part number reel length (m) outside dia (mm) inside dia (mm) min inside bend radius (mm) FPPDS part number reel length (m) outside dia (mm) inside dia (mm) min inside bend radius (mm) Conduit Clip FCLAMP FCL10 FPADS11* 50 11.5 6.2 70 FPRDS11 50 11.5 6.2 70 FPPDS11 50 11.5 6.2 70 FPADS13 50 13.0 7.9 75 FPRDS13 50 13.0 7.9 75 FPPDS13 50 13.0 7.9 75 FCL13 FPADS16 50 15.8 10.3 100 FPRDS16 50 15.8 10.3 100 FPPDS16 50 15.8 10.3 100 FCL16 FCLAMP- 3-16 FCL18 FCL20 FPADS21 50 21.2 13.9 120 FPRDS21 50 21.2 13.9 120 FPPDS21 50 21.2 13.9 120 FCL21 FCLAMP- 3-21 FCL21 FCLAMP- 3-21 FCL25 FCL28 FCLAMP- 4-28 FPADS28 50 28.5 20.5 170 FPRDS28 50 28.5 20.5 170 FPPDS28 50 28.5 20.5 170 FCL28 FCLAMP- 4-28 FPADS34 25 34.5 26.6 180 FPRDS34 25 34.5 26.6 180 FPPDS34 25 34.5 26.6 180 FCL34 FCLAMP- 5-34 FPADS42 25 42.5 32.0 200 FPRDS42 25 42.5 32.0 200 FPPDS42 25 42.5 32.0 200 FCL42 FCLAMP- 6-42 FPADS54 25 54.5 43.0 240 FPRDS54 25 54.5 43.0 240 FPPDS54 25 54.5 43.0 240 FCL54 FCLAMP- 7-54 FCL67 FCLAMP- 7-67 FCLAMP- 8-80 F = fine pitch C = coarse pitch For larger diameter conduit see page 70 Ordering Notes • Specify colour (B = Black, G = Grey) and reel length eg: FPP16B-50M for a Black 50m reel • Some lengths are MTO in Grey • FPPH available on request * Indicates parts made to order on request and maybe subject to MOQ and lead time. • Available on request: - longer lengths and bulk packaging - cut lengths and assemblies - additional sizes - other colours • Hinged fitting available for 21mm double slit conduit - FDF21-M20B NEW NEW NEW Allied Tube & Conduit 46 atkore.com/flexicon pitch nominal size (mm) european (NW) sizes F 10 7 F 11 8 F 13 10 F 16 12 F 18 14 C 20 F 21 17 C 21 C 25 F 28 23 C 28 23 C 34 29 C 42 36 C 54 48 C 67 56 C 70 80 C 95 106 Abrasion Rings AR16B AR21B AR28B AR34B AR42B AR54B Construction: Double slit nylon (highly flame retardant PA6) corrugated conduit. Colour: Black. Typical Applications: Retrofit and cable assemblies where Low Fire Hazard performance is required, i.e. Rail Industry. • Made from 2 interlocking slit corrugated conduits • Temperature range -40˚C to +120˚C • Cables can be inserted laterally • Provides abrasion resistance and routing of cables for static applications • Self extinguishing • Halogen, sulphur and phosphorus free • ExtraLowFireHazard(LFH) • Compliant toLULStdS1085 • UL94V0 flame retardancy • EN 45545 HL3 Interior R22 and exterior R23 • NFPA 130 • Highly resistant to solvents and oils • UV resistant Construction: Double slit polypropylene corrugated conduit. Colour: Black. Typical Applications: Retrofit and cable assemblies where basic mechanical cable protection is required. • Made from 2 interlocking slit corrugated conduits • Temperature range -20˚C to +90˚C • Cables can be inserted laterally • Provides abrasion resistance and routing of cables for static applications • Self extinguishing • Acid resistant • Also available as a handy Contractor pack – see page 128 STANDARD LOW FIRE HAZARD EXTRA LOW FIRE HAZARD INHERENT LOW FIRE HAZARD STANDARD LOW FIRE HAZARD EXTRA LOW FIRE HAZARD INHERENT LOW FIRE HAZARD

RkJQdWJsaXNoZXIy NTk2NDg=